Taylor Replacement Reagent R-0001 - .75 oz - R-0001-A-24

Ahorrar 69%
TAYLOR TECHNOLOGIES INCSKU: R-0001-A-24

Precio:
Precio de venta$5.49 Precio habitual$17.46
Stock:
Solo queda 1 unidad

Retiro disponible en The Pool Supply Warehouse

Normalmente está listo en 24 horas

Envíos con cero emisiones de carbono con Shopify Planet
Envíos neutros en carbono en todos los pedidos
2,222kg
emisiones por envíos eliminadas
Equivalente a...
5,688
millas recorridas por un vehículo de gasolina promedio
Financiamos innovaciones en...
Captura directa de aire
Biopetróleo
Mineralización

The Taylor R-0001 #1 DPD Reagent Solution is an inorganic salt solution and is a direct replacement for DPD reagents in Taylor test kits. Test kit reagents should be stored in a cool, dry place out of direct sunlight and should be replaced at least annually.

REAGENT SHELF LIFE

All reagents have a shelf life, whether they are liquids, powders, crystals, tablets, or test-strip pads. If kept dry, powders and crystals are very stable; acids are also long lived. Date of manufacture is not the controlling factor when it comes to shelf life—storage conditions are more important. As with all perishables, reagents are sensitive to environmental influences and will last longer under controlled conditions.

To this end, we recommend:

  • Storing reagents at a consistent temperature in the range if 36°–85°F (2°–29°C); extreme temperature fluctuation, say from a refrigerator to a hot car trunk, causes reagents to deteriorate.
  • Keeping them out of prolonged direct sunlight. (Note: their brown plastic bottles help protect very light-sensitive reagents.)
  • Segregating reagents from containers of treatment chemicals.
  • Replacing caps immediately and tightening them carefully so that exposure to air and humidity is limited.
  • Avoiding switching bottle caps, placing bottle caps on soiled surfaces, repouring reagents into contaminated containers, or touching test strip pads.

Taylor formulates its reagents to remain effective for at least one year, with only very few exceptions (molybdenum indicator in liquid form is one; after four months old it should be tested against a standard periodically). As a general precaution, replace all reagents more than one year old, or at the beginning of a new testing season.

Boiling Point212° F
BrandTaylor
Chemical Composition80-90% Water, 5-10% Dipotassium Phosphate, 5-10% Disodium phosphate, 0.01−0.1% Other Components Below Reportable Levels
ColorClear
Container Size0.75 oz
Container TypeDropper Bottle
FormLiquid
ItemDPD Reagent #1
OdorOdorless
PH Range10
Shelf Life1-Year
SolubilitySoluble in All Proportions
Standards Approvals29 CFR 1910.1200
Storage Temperature36-85° F (2-29° C)
Vapor Density0.64
Vapor Pressure17 mm Hg

You may also like